Work environment indicators: ● Power supply: 50Hz AC180V ~ 240v ● Operating Temperature: -40 ~ +50 ℃ ● Storage temperature: -50 ~ +120 ℃ ● Operating Humidity: ≤ 95%
Output pulses indicators: ● output high voltage pulse peak: 5KV ~ 10KV ● output low-voltage pulse peak: 700 ~ 1000V ● pulse peak current: ≤ 10A ● Pulse duration: ≤ 0.1s ● pulse interval:> 1s ● single pulse output power: 2.5mC ● The maximum energy of a single pulse output: ≤ 5.0J ● System power consumption: <15W
System features:
1. difference voltage output technology: every line has voltage, there is voltage difference between adjacent lines.
2. With 5 LED working mode indicated lamp, respectively displaying power supply, armed/ disarmed, tamper, short circuit, break.
3. high/ low voltage switch manually, automatic switch function by long distance equip.
4. short circuit, break and tamper alarm, self-detect equip fault.
5. set the alarm delay time freely.
6. plastic casing with water proof design suitable industry development.
7. RS485 long distance control, keypad, computer, network, multiple management solution.
8. DC 12V and constant open/close alarm output used for acousto-optic alarm and other security equip linkage.
|